Netgear Switch M4100 Manuale Utente Pagina 399

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 559
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 398
Chapter 24. Double VLANs and Private VLAN Groups | 399
ProSafe M4100 and M7100 Managed Switches
The following example shows how to configure the NETGEAR switch shown in the preceding
figure to add a double VLAN tag for traffic going from the subnet domain connected to port
1/0/24. This example assumes there is a Layer 2 switch connecting all these devices in your
domain. The Layer 2 switch tags the packet going to the NETGEAR switch port 1/0/24. The
example is shown as CLI commands and as a Web interface procedure.
CLI: Enable a Double VLAN
Create a VLAN 200.
(Netgear Switch)#vlan database
(Netgear Switch) (Vlan)#vlan 200
(Netgear Switch) (Vlan)#exit
Add interface 1/0/24 to VLAN 200, add pvid 200 to port.
(Netgear Switch) #config
(Netgear Switch) (Config)#interface 1/0/24
(Netgear Switch) (Interface 1/0/24)#vlan pvid 200
(Netgear Switch) (Interface 1/0/24)#vlan participation include 200
(Netgear Switch) (Interface 1/0/24)#exit
Add interface 1/0/48 to the VLAN 200 in a tagging mode.
(Netgear Switch) (Config)#interface 1/0/48
(Netgear Switch) (Interface 1/0/48)#vlan participation include 200
(Netgear Switch) (Interface 1/0/48)#vlan tagging 200
(Netgear Switch) (Interface 1/0/48)#exit
Select interface 1/0/48 as the provider port.
(Netgear Switch) (Config)#
(Netgear Switch) (Config)#interface 1/0/48
(Netgear Switch) (Interface 1/0/48)#mode dvlan-tunnel
(Netgear Switch) (Interface 1/0/48)#exit
Web Interface: Enable a Double VLAN
1. Create static VLAN 200:
Vedere la pagina 398
1 2 ... 394 395 396 397 398 399 400 401 402 403 404 ... 558 559

Commenti su questo manuale

Nessun commento